The LQ-850, LQ-950 and LQ-1050 have two 8-position DIP switches.
These switches are located at the rear of the printer.

CountrySW 1-1SW 1-2SW 1-3
USAONONON
FranceONONOFF
GermanyONOFFON
United KingdomONOFFOFF
DenmarkOFFONON
SwedenOFFONOFF
ItalyOFFOFFON
SpainOFFOFFOFF



SwitchONOFF
SW 1-4Graphic CharactersItalic Characters
SW 1-5Unidirectional GraphicsBidirectional Graphics
SW 1-6Not UsedNot Used
SW 1-7CSF EnabledCSF Disabled
SW 1-80K Input Buffer
User-Defined
Characters Enabled
6K Input Buffer
User-Defined
Characters Disabled
SW 2-112" Page Length11" Page Length
SW 2-21" Skip over PerfSkip over Perf Inactive



Interface/ParitySW 2-3SW 2-4
ParallelOFFOFF
Serial/EvenOFFON
Serial/OddONOFF
Serial/NoneONON



Baud RateSW 2-5SW 2-6
9600OFFOFF
*4800/19200ONOFF
1200OFFON
300ONON



SwitchONOFF
SW 2-7Tear Off Mode ONTear Off Mode OFF
SW 2-8CR Produces CR + LFCR Only



*NOTE - Baud rate of 19200 is available with N9xxxx firmware only.